**This page answers common hardware and software questions from engineers integrating Quectel cellular modules into their devices: audio output and voice calls, flash memory, MMS and phonebook commands, PPP dial-up, power supply design, RF and antenna layout, SIM card detection and network registration, SMS, the UART serial interface, and the module's embedded TCP/UDP stack.**

**Scope:** several answers were written for Quectel GSM/GPRS modules. They refer to GPRS multislot class and GPRS peak current, use commands such as `AT+QGPCLASS`, and the evaluation-board photos show the Quectel M10 EVB. AT command names, parameters and limits differ between module families, so confirm each command in the AT Commands Manual for your module in the [Quectel Download Zone](https://www.quectel.com/download-zone/?utm_source=agentedge_md&utm_medium=ai_agent&utm_campaign=ai_ready_faq_v1&utm_content=faq_technical_download_zone).

## Key takeaways

- **Powering from a vehicle supply (12/24/48 V):** use two stages — a DC-DC converter down to 5 V, then an LDO down to about 4 V. Do not drop 5 V to 4.4 V with a diode. → [Power supply](#power-supply-design-and-sleep-current-testing)
- **Powering from USB:** a standard USB port gives at most 500 mA, below the peak current of GPRS modules; it only works with GPRS class 8, large low-ESR capacitors and a weak-signal test. → [Power supply](#power-supply-design-and-sleep-current-testing)
- **Antenna layout:** keep the antenna away from DC-DC converters, power lines, the LCD, the CPU and memory, and the SIM card; keep antennas of neighboring modules more than 20 cm apart. → [RF and antenna design](#rf-and-antenna-design)
- **SIM card lost after running for a while:** the usual causes are RF interference, a VBAT trace routed near the SIM lines, or a poor-quality SIM card. → [SIM card](#sim-card-detection-recognition-and-network-registration)
- **"SEND OK" does not mean the server received the data:** it means the data reached the module's TCP socket buffer; check delivery with `AT+QISACK`. → [TCP/UDP](#tcpudp-embedded-ip-stack-limits-and-behavior)
- **SMS length:** 160 characters (GSM 7-bit), 140 (8-bit) or 70 (UCS2) per message; a long SMS can contain up to 7 messages. → [SMS](#sms-text-and-pdu-mode-message-length-and-storage)

Jump to: [Quick reference](#quick-reference-limits-and-values) · [Troubleshooting by symptom](#troubleshooting-by-symptom) · [Audio and calls](#audio-output-and-voice-calls) · [Flash](#flash-memory-endurance) · [MMS](#mms-character-encoding) · [Phonebook](#phonebook-and-subscriber-number) · [PPP](#ppp-dial-up) · [Power supply](#power-supply-design-and-sleep-current-testing) · [RF](#rf-and-antenna-design) · [SIM card](#sim-card-detection-recognition-and-network-registration) · [SMS](#sms-text-and-pdu-mode-message-length-and-storage) · [UART](#uart-serial-communication) · [TCP/UDP](#tcpudp-embedded-ip-stack-limits-and-behavior)

## Quick reference: limits and values

Values as stated in the answers on this page. Limits for a specific module are defined in its AT Commands Manual and Hardware Design document.

| Item | Value | Section |
|---|---|---|
| Speaker load the audio output can drive | 8 Ω with an embedded class-AB amplifier; 32 Ω without (add an external amplifier for 8 Ω) | [Audio](#audio-output-and-voice-calls) |
| Capacitors allowed on the audio interface | 10 pF and 33 pF (for RF interference); capacitors above 1 µF can make calls hang up | [Audio](#audio-output-and-voice-calls) |
| Maximum time for `OK` after `ATH` | 90 seconds (3GPP) | [Calls](#audio-output-and-voice-calls) |
| Flash memory endurance | About 100,000 erase cycles, extended by wear leveling | [Flash](#flash-memory-endurance) |
| Standard USB port output current | Max. 500 mA | [Power supply](#power-supply-design-and-sleep-current-testing) |
| VBAT when powering from USB | 4.2–4.5 V, with two low-ESR 2200 µF capacitors near the module | [Power supply](#power-supply-design-and-sleep-current-testing) |
| Spacing between antennas of neighboring modules | More than 20 cm | [RF](#rf-and-antenna-design) |
| External lightning-protection TVS on RF_IN | Capacitance below 0.5 pF | [RF](#rf-and-antenna-design) |
| Maximum GPRS user data rate | 85.6 kbps (GPRS multislot class 12, 4 timeslots, CS-4) | [RF](#rf-and-antenna-design) |
| Capacitors from SIM signal lines to ground | 15–33 pF | [SIM card](#sim-card-detection-recognition-and-network-registration) |
| Single SMS size | 1120 bits: 160 characters (GSM 7-bit), 140 (8-bit), 70 (UCS2) | [SMS](#sms-text-and-pdu-mode-message-length-and-storage) |
| Messages in one long SMS | Up to 7 | [SMS](#sms-text-and-pdu-mode-message-length-and-storage) |
| SMS initialization after power-on | About 20 s; about 40 s with some SIM cards | [SMS](#sms-text-and-pdu-mode-message-length-and-storage) |
| TCP domain name length | Max. 99 bytes | [TCP/UDP](#tcpudp-embedded-ip-stack-limits-and-behavior) |
| APN length | Max. 31 bytes | [TCP/UDP](#tcpudp-embedded-ip-stack-limits-and-behavior) |
| Data per `AT+QISEND` | Max. 1460 bytes | [TCP/UDP](#tcpudp-embedded-ip-stack-limits-and-behavior) |
| Value of each `AT+QISACK` parameter | 32-bit, max. 4294967295 (2³² − 1) | [TCP/UDP](#tcpudp-embedded-ip-stack-limits-and-behavior) |
| Retransmissions before the module closes a TCP connection | 12 | [TCP/UDP](#tcpudp-embedded-ip-stack-limits-and-behavior) |

## Troubleshooting by symptom

| Symptom | Check first | Section |
|---|---|---|
| A call hangs up after dialing with `ATD` | Whether the MCU sent `ATH`; capacitors above 1 µF on the audio interface | [Audio and calls](#why-does-a-call-hang-up-after-dialing-with-atd) |
| PPP dial-up fails | Serial port in use by another tool, baud rate mismatch, APN, flow control, SIM PIN lock or unpaid SIM | [PPP](#what-causes-ppp-dial-up-to-fail) |
| Module does not register with the network after power-on | `AT+CPIN`, SIM service status, `AT+QBAND` / `AT+CFUN`, `AT+CSQ`, `AT+GSN` | [SIM card](#why-does-the-module-not-register-with-the-network-after-power-on) |
| SIM card stops being recognized after a while | RF interference, VBAT trace near SIM lines, SIM card quality | [SIM card](#why-is-the-sim-card-no-longer-recognized-after-the-module-runs-for-a-while) |
| Several modules close together lose signal or fail to register | Antenna spacing, QuecScan/QuecLock frequency locking, SIMs from different operators | [RF](#what-happens-when-several-modules-work-close-together) |
| No response on the UART | STATUS pin level, serial cable and RTS setting, baud rate, hardware flow control | [UART](#how-do-i-fix-uart-communication-failure) |
| SMS commands return ERROR right after power-on | SIM/SMS initialization not finished; check `AT+QINISTAT` | [SMS](#why-do-sms-commands-return-error-right-after-power-on) |
| Incoming SMS messages are not received | SMS memory full | [SMS](#can-the-module-receive-sms-when-sms-memory-is-full) |
| Server has not received data after `SEND OK` | Check acknowledgment with `AT+QISACK` | [TCP/UDP](#why-has-the-server-not-received-data-after-the-module-responds-send-ok) |
| Unexpected `CLOSED` on a TCP connection | Server closed it, 12 failed retransmissions, or network interruption | [TCP/UDP](#when-does-the-module-respond-closed) |
| Module power supply unstable after a diode drop from 5 V | Replace the diode with a proper regulator | [Power supply](#can-i-use-a-diode-to-drop-a-5-v-supply-to-44-v-for-the-module) |

## Audio output and voice calls

### What speaker load can a Quectel module's audio output drive?
A module with an embedded class-AB amplifier can drive a load down to 8 Ω. Without an embedded class-AB amplifier, the audio output can drive a load down to 32 Ω, and an external audio amplifier is needed to drive an 8 Ω speaker.

### Why does a call hang up after dialing with ATD?
Check two things:
1. Whether the MCU has sent an `ATH` command that ended the call.
2. Whether there are high-value capacitors (more than 1 µF) on the audio interface. Normally only 10 pF and 33 pF capacitors should be connected to the audio interface, to suppress RF interference. Larger capacitors make the audio PA unstable, which can make the call hang up.

### How do I set up caller ID (CLIP) and connected line identification (COLP)?
1. `AT+CLIP=1` presents the calling line. Set `AT+QCLIP=1` to also present the name saved for that number in the phonebook.
2. `AT+COLP=1` presents the connected line. Set `AT+QCOLP=1` to also present the name saved for that number in the phonebook.

Example:
```
AT+CPBW=1,"02151082965",129,"QUECTEL"  //write phonebook entry
OK
AT+QCLIP=1  // present the string type corresponding to the entry saved in the phonebook
OK
AT+CLIP=1  //calling line identification enabled
OK
RING
+CLIP: "02151082965",129,"",,"QUECTEL",0  // "QUECTEL" will be presented
AT+QCOLP=1  // present the string type corresponding to the entry saved in the phonebook
OK
AT+COLP=1  //connected line identification enabled
OK
ATD02151082965;
+COLP: "02151082965",129,"",0,"QUECTEL"  // "QUECTEL" will be presented
```

### How long can the module take to respond OK after ATH hangs up a call?
Up to 90 seconds, the maximum allowed by the 3GPP standard. Set the `ATH` timeout in the MCU program accordingly.

## Flash memory endurance

### What is the lifetime of the module's flash memory?
Flash memory typically endures about 100,000 erase cycles. Quectel modules extend this with dynamic read/write (wear leveling): data is written across all sections of the flash instead of the same block, so every section is used evenly and no single block wears out early.

## MMS character encoding

### Does MMS support UTF-8 and UCS2 encoding, and which is better?
Both UTF-8 and UCS2 are supported. UTF-8 is recommended for better network compatibility.

## Phonebook and subscriber number

### How do I configure and query the subscriber (own) number?
```
AT+CPBS="ON" //choose "ON" phonebook type
AT+CPBW=1,"number" //write subscriber number
AT+CNUM  //query subscriber number
```

### How do I write and read a phonebook entry on the SIM card?
```
AT+CPBS="SM"  //choose "SM" phonebook type, which is to operate the phonebook saved in the SIM card
AT+CSCS="GSM"  //set the phonebook number and name as GSM format
AT+CPBW=1,"number"  //write phonebook entry whose index is 1
AT+CPBR=1  //read phonebook entry whose index is 1
```

## PPP dial-up

### How do I set up a PPP dial-up connection in Windows 7?
1. Open **Network and Sharing Center** in the Control Panel.
2. Choose **Set up a new connection or network**.
3. Choose **Set up a dial-up connection**.
4. Choose **Skip** on the next screen.
5. Choose **Change adapter settings**.
6. Open the connection's **Properties**, set the baud rate to 115200 on the General tab, and click **OK**.
7. Choose **Dial** to complete the PPP dial-up.

These steps were written for Windows 7; menu names differ in later Windows versions.

### What causes PPP dial-up to fail?
Check the following:
1. Is the serial port being used by another serial tool while dialing?
2. Do the baud rates of the module, the modem configuration and the dial-up connection match?
3. Is the APN configured correctly in the modem?
4. Is the device wired with five wires or three wires, and is hardware flow control enabled or disabled to match?
5. Is the SIM card PIN-locked, or is the SIM account in arrears?

## Power supply design and sleep-current testing

### Can I use a diode to drop a 5 V supply to 4.4 V for the module?
No. A diode's forward voltage changes with current, so the module's supply voltage becomes unstable and the module can behave abnormally.

### Can a module be powered from a standard USB port?
Only with precautions. A standard USB port supplies at most 500 mA, which does not meet the peak current of GPRS modules. To power a module from USB:
1. Use `AT+QGPCLASS` to set the GPRS multislot class to 8. This takes effect after the module restarts; class 8 uses only one uplink timeslot.
2. Connect two low-ESR 2200 µF capacitors to the VBAT pin, close to the module.
3. Set VBAT between 4.2 V and 4.5 V, so a voltage drop on VBAT does not make the module behave abnormally.
4. Test the module at weak signal (for example, a CSQ value below 14). If it works properly, it can be powered from the USB port.

### How do I power a module from 12 V, 24 V or 48 V (for example, in a vehicle)?
Use two-stage conversion: first step down to 5 V with a DC-DC converter, then from 5 V to about 4 V with an LDO.

![Two-stage power supply: DC 12 V input to DC-DC converter (LM2596S-5V) for 5 V, then LDO (PAM3116A) for a 4 V module supply](https://www.quectel.com/content/uploads/2021/03/Power-Supply-Annotation1.png)

### How do I measure the module's power consumption in sleep mode?
Power the module on its own so peripheral circuits do not add current. Connect only VBAT, GND, SIM, RF and PWRKEY; the current drawn on VBAT is then the module's own consumption.

To measure on the evaluation board (the photos show the Quectel M10 EVB):
1. Remove resistors R110 and R102.
2. Fit R224 with a 0 Ω resistor.
3. Plug in the power adapter and turn on the 5 V power switch.

![Quectel M10 EVB with the J103 VBAT header and the 5 V power switch marked](https://www.quectel.com/content/uploads/2021/03/Chipboard-1.png)
![Quectel M10 EVB detail for the sleep-current measurement setup](https://www.quectel.com/content/uploads/2021/03/Chipboard-2.png)

Notes:
1. Removing R110 makes the module draw power directly from the external supply through J103.
2. The power adapter must stay plugged in to power the RS232 converter and LEDs; otherwise sink current adds to the measured consumption.
3. The module's VDD_EXT normally powers the RS232 converter. Remove R102 so VDD_EXT no longer powers it, and fit R224 with a 0 Ω resistor so the 5 V adapter powers the RS232 converter instead.

## RF and antenna design

### What should I consider when designing with an embedded antenna?
1. Choose a DC-DC converter with a low switching frequency.
2. Route the DC-DC converter's input and output lines, and all other power supplies, away from the antenna.
3. Keep the antenna away from the LCD, especially the LCD's FPC.
4. Keep the antenna and RF trace away from the main CPU, SDRAM and flash. Add EMI filters on the high-speed lines of the CPU, SDRAM and flash.
5. Cover the CPU, SDRAM, flash and DC-DC converter with a shielding can.
6. Keep the antenna away from the SIM card.
7. Do not use metal for the enclosure or structural parts around the antenna.
8. The enclosure and nearby components affect RF performance, so give the device to the antenna vendor to optimize the antenna. Quectel provides antenna design reference documents in the Download Zone and offers [antenna services](https://www.quectel.com/iot-antenna-services/).

### Can the RF pin withstand a lightning surge?
No. The TVS inside the module only protects against ESD. If the device must withstand lightning surges, add a dedicated lightning-protection TVS on the RF_IN pin outside the module, with a capacitance below 0.5 pF.

### What happens when several modules work close together?
1. **Interference:** antennas placed too close together cause EMI, which lowers signal quality, raises the bit error rate and can cause persistent connection problems or connection failure. Keep each antenna more than 20 cm from the others.
2. **Network capacity:** many modules working at once can exhaust base-station resources, so some modules fail to register. Use the QuecScan/QuecLock function to lock modules to different frequencies, and use SIM cards from different operators where possible.

### What is the maximum GPRS data rate?
85.6 kbps. With GPRS multislot class 12, uplink and downlink each use 4 timeslots, and coding scheme CS-4 carries 21.4 kbps per timeslot (4 × 21.4 = 85.6 kbps). Actual speed depends on the network; for example, the average measured in Shanghai was 30 kbps.

![GPRS coding schemes CS-1 to CS-4: data rate per timeslot 9.06, 13.4, 15.6 and 21.4 kbps](https://www.quectel.com/content/uploads/2021/03/GPRS-Coding-Scheme.png)

| Coding scheme | Code rate | Data rate per timeslot |
|---|---|---|
| CS-1 | 1/2 | 9.06 kbps |
| CS-2 | ≈2/3 | 13.4 kbps |
| CS-3 | ≈3/4 | 15.6 kbps |
| CS-4 | 1 | 21.4 kbps |

## SIM card detection, recognition and network registration

### How do I enable SIM card hot-swap?
1. Make sure the module's SIM_PRESENCE pin is connected.
2. Enable SIM card detection with AT commands:

```
AT+QSIMSTAT=1                        // Enable SIM inserted status report
AT+QSIMDET=1,1  or  AT+QSIMDET=1,0   // Enable SIM card presence detection
```

When the SIM card is removed or inserted, the module responds immediately:
```
+CPIN: NOT READY
+QSIMSTAT: 1,0   or   +QSIMSTAT: 1,1
Call Ready
```

### Why is the SIM card no longer recognized after the module runs for a while?
If the module responds `+CPIN: READY` after power-on but later responds `+CPIN: NOT READY`, check three causes:

1. **RF interference**
   - Use `AT+CFUN=4,1` to disable RF and see whether the problem continues.
   - Move the antenna close to the SIM card and SIM lines and see whether the problem happens more often.
   - Check for strong electric or magnetic fields near the test site, such as high-voltage power lines or high-power radio equipment, and try covering the SIM card and all SIM lines with a shielding can.
   - Connect the SIM signal pins (`SIM_DATA`, `SIM_CLK`, `SIM_RST`, `SIM_VDD`) to ground through 15–33 pF capacitors.
2. **Hardware design:** if the VBAT trace runs too close to the SIM lines, the SIM is still recognized at power-on because VBAT ripple is low, but ripple rises when the module registers with the network and can disturb the SIM lines. Disconnect the module's own supply and feed the VBAT pin directly from an external source to see whether the problem goes away.
3. **SIM card quality:** try another SIM card, and test the problem card in a Quectel EVB or a phone.

### Why does the module not register with the network after power-on?
1. Use `AT+CPIN` to check that the module recognizes the SIM card.
2. Check that the SIM card is in service.
3. Use `AT+QBAND` and `AT+CFUN` to check the module's working band and functionality mode.
4. Use `AT+CSQ` to check that the RF signal is normal.
5. Use `AT+GSN` to check that the module's IMEI is valid. Networks in some areas treat a changed IMEI as illegal and refuse registration.

## SMS: text and PDU mode, message length and storage

### What is the difference between SMS text mode and PDU mode?
- **Text mode:** set parameters with AT commands such as `AT+CMGF`, `AT+CSCS` and `AT+CSMP`.
- **PDU mode:** put all parameters, such as the SMS center number, recipient number and validity period, into one PDU string.

### What is the maximum length of a single SMS?
1120 bits, as defined by 3GPP. The number of characters depends on the encoding:

| Encoding | Maximum characters |
|---|---|
| GSM 7-bit alphabet | 160 (1120 ÷ 7) |
| 8-bit data | 140 (1120 ÷ 8) |
| UCS2 16-bit | 70 (1120 ÷ 16) |

### What is a long SMS (concatenated SMS)?
A long SMS is split into several short messages that are sent separately; the receiving device reassembles them and shows one message. Each short message starts with a User Data Header (UDH) that carries the segmentation information, and the TP-UDHI flag is set to 1. On Quectel modules, a long SMS can contain up to 7 short messages.

### Can the module receive SMS when SMS memory is full?
No. Incoming messages cannot be received while SMS memory is full. After `AT+QEXTUNSOL="SM",1`, the module reports `+TSMSINFO: 322` when SMS memory becomes full.

### Why do SMS commands return ERROR right after power-on?
SIM card initialization has not finished. It usually completes about 20 seconds after power-on, or about 40 seconds with some SIM cards because of their electrical characteristics. Check with `AT+QINISTAT`; `+QINISTAT: 3` means SMS initialization is complete.

Until then, these commands return an error: `QMGDA`, `CGSMS`, `CSMS`, `CMGL`, `CSAS`, `CRES`, `CMSS`, `CSCB`, `CMGW`, `CMGD`, `CMGR`, `CPMS`.

## UART serial communication

### How do I fix UART communication failure?
First check the STATUS pin: high means the module is on, low means it is off. If the module is on, check the connection that is failing.

**Between a PC and the EVB**
1. Check the serial cable. The Quectel serial cable is recommended; it avoids communication problems that a three-wire cable can cause when hardware flow control is on.
2. Check the serial tool settings. In Quectel's QCOM tool, tick **RTS**:

![QCOM serial tool Operation panel with the RTS box ticked](https://www.quectel.com/content/uploads/2021/03/Serial-Annotation2.png)

**Between an MCU and the module**
1. Check that the MCU's baud rate matches the module's. Quectel modules use autobauding by default: send 2–4 AT commands to synchronize (some modules need more). After synchronizing, fix the baud rate with `AT+IPR` and save it with `AT&W`.
2. If the MCU and module are connected with three wires, make sure hardware flow control is disabled.

### How do I match UART voltage levels between the MCU and the module?
Use a level-shift circuit between the MCU and the module:

- **3.3 V MCU:** use a 3.3 V level-shift circuit; see the Hardware Design document for your module.
- **3 V MCU:** change the 5.6 kΩ resistor in the level-shift circuit to 15 kΩ.
- **5 V MCU:** use the level-shift circuit below.

![UART level-shift circuit for a 5 V MCU: transistor stages on TXD and RXD with 4.7 kΩ and 5.6 kΩ resistors between VCC_MCU and the module's VDD_EXT](https://www.quectel.com/content/uploads/2021/03/serialiii.png)

## TCP/UDP: embedded IP stack limits and behavior

### What is the maximum length of a TCP domain name?
99 bytes.

### What is the maximum APN length?
31 bytes.

### How can the module receive data on a TCP/UDP connection?
- **Non-transparent mode**, two options:
  1. Direct push: received data is output directly on the UART.
  2. Buffer access: received data is kept in an internal buffer and read with AT commands.
- **Transparent mode:** received data is output directly on the UART only.

### What is the maximum length of data sent with AT+QISEND?
1460 bytes.

### What is the maximum value returned by AT+QISACK?
Each parameter returned by `AT+QISACK` is a 32-bit value, as in the TCP protocol, so the maximum is 4294967295 (2³² − 1).

### Why has the server not received data after the module responds SEND OK?
`SEND OK` only means the data has been placed in the TCP socket buffer, not that the server has received it. Use `AT+QISACK` to check whether the server has acknowledged the data.

### When does the module respond CLOSED?
1. The server closes the TCP connection.
2. The module still receives no ACK from the server after 12 retransmission attempts, so it closes the connection itself.
3. The TCP connection is interrupted by a network fault.

### What is the difference between AT+CGDCONT and AT+QICSGP?
Use `AT+QICSGP` to set the APN when using the module's embedded TCP/UDP stack. Use `AT+CGDCONT` to set the APN when using PPP.

## Related resources

- [Technical support request form](https://www.quectel.com/tech-support/?utm_source=agentedge_md&utm_medium=ai_agent&utm_campaign=ai_ready_faq_v1&utm_content=faq_technical_support_form) – product integration, troubleshooting and documentation requests
- [Quectel Download Zone](https://www.quectel.com/download-zone/?utm_source=agentedge_md&utm_medium=ai_agent&utm_campaign=ai_ready_faq_v1&utm_content=faq_technical_download_zone) – AT Commands Manuals, Hardware Design documents, application notes and drivers (free account)
- [Quectel forums](https://forums.quectel.com/) and the [technical support thread](https://forums.quectel.com/t/technical-support/2580)
- [Masterclass IoT webinars](https://www.quectel.com/masterclass/) and the [Masterclass library](https://www.quectel.com/masterclass-library/) (recorded videos)
- [Antenna services](https://www.quectel.com/iot-antenna-services/) and [testing and certification services](https://www.quectel.com/testing-certification-services/)
- [Product selector](https://www.quectel.com/product-selector/)
- [General FAQs](https://www.quectel.com/faqs-general/) – company information, quotations, distributors, Download Zone accounts
- **Quotations and pricing:** email [sales-support@quectel.com](mailto:sales-support@quectel.com) with your company and location, end customer, application and estimated annual volume

## About Quectel

Quectel Wireless Solutions Co., Ltd. is a global IoT solutions provider of cellular, GNSS, Wi-Fi and Bluetooth modules, antennas and services, headquartered in Shanghai, China. [Company](https://www.quectel.com/company/) · [Contact](https://www.quectel.com/contact/) · [www.quectel.com](https://www.quectel.com/)

## Sources, version and review scope

Content comes from the Quectel Technical FAQs page (HTML last modified 25 February 2026), restructured and reviewed on 14 November 2026. Changes from the source: the `AT+QISACK` maximum is corrected from 4294967296 to 4294967295 (2³² − 1); "TP-UDH1" is corrected to the User Data Header with TP-UDHI set to 1; an empty "For detail you can refer to" reference is removed; the 5 V level-shift diagram is shown once, because the source page shows the same 5 V diagram under both 3.3 V and 5 V and has no 3.3 V diagram; section numbering is removed. AT commands, values and procedures are otherwise unchanged and are not verified against each module family.